Evidence & Standards

Other Water Evidence and Standards

This page summarises available evidence and test-report references for the Other Water Nova 100 countertop reverse osmosis water purifier. It is intended to help customers, support teams, search engines, and AI discovery systems understand the available product evidence, test scope, standards references, and limitations.

Overview

What this page covers

This page brings together available evidence references for the Nova 100 countertop reverse osmosis water purifier. It includes an EMC report summary, water quality test report summary, standards referenced in the EMC report, selected water quality test results, spiked water test results, hygiene safety information, desalination rate information, and evidence scope notes.

The information below is based on the evidence files currently available to Other Water. It should be read together with the product page, user manual, and official report documents supplied by the brand.

Current Evidence

Nova 100 evidence available today

Product Other Water NOVA 100 water purifier
Brand / Client named in EMC report OTHER WATER LIMITED, 50a London Street, Reading, RG1 4SQ, United Kingdom
EMC report TÜV Rheinland EMC service report, report number CN24X4EK 004
Water quality report JIA HE TESTING report number JWCjs-25-20769, English Translation Version
Report 1 of 2

TÜV Rheinland EMC report summary

TÜV Rheinland

Electromagnetic compatibility report for Nova 100

Report number CN24X4EK 004 · TÜV Rheinland (Shanghai) Co., Ltd. · Issue date 2026-03-17

The available EMC report is a TÜV Rheinland test report for products. The report identifies the test item as a water purifier and the model as Other Water NOVA 100. The order content is listed as TÜV Rheinland EMC service.

Report item Available detail
Testing body TÜV Rheinland (Shanghai) Co., Ltd.
Test report number CN24X4EK 004
Order number 326144367
Client reference number 2743070
Client OTHER WATER LIMITED
Client address 50a London Street, Reading, RG1 4SQ, United Kingdom
Test item Water purifier
Identification / type no. Other Water NOVA 100
Order content TÜV Rheinland EMC service
Date of sample receipt 2026-02-09
Test sample number 326144367-1-1
Test result Pass
Issue date 2026-03-17
Condition of test item at delivery Test item complete and undamaged
Scope note The EMC report relates to the tested sample described in the report. The report also states that it does not entitle the use of a test mark. This page therefore describes the available report reference and result, not a separate test-mark licence.
EMC Standards

Standards referenced in the EMC report

The TÜV Rheinland EMC report lists the following BS EN and BS EN IEC test specifications:

BS EN IEC 55014-1:2021
BS EN IEC 55014-2:2021
BS EN IEC 61000-3-2:2019+A1
BS EN 61000-3-3:2013+A2
BS EN 55014-1:2017+A11
BS EN 55014-2:1997+A2
BS EN 61000-3-2:2014
BS EN 61000-3-3:2013
Report 2 of 2

Water quality test report summary

JIA HE TESTING

Water quality, RO performance and hygiene safety report

Report number JWCjs-25-20769 · English Translation Version · Original sealed Chinese report prevails

The available water quality test evidence is from JIA HE TESTING, report number JWCjs-25-20769. The document is labelled as an English Translation Version and states that the original sealed Chinese report prevails.

Report item Available detail
Testing body shown JIA HE TESTING
Report number JWCjs-25-20769
Language note English Translation Version. Original sealed Chinese report prevails.
Report coverage shown Water quality tables, returned concentrate water testing, spiked water testing, hygiene safety testing, and desalination rate testing.
Testing body profile shown Jiahe Testing Co., Ltd., a wholly-owned subsidiary of China Household Electric Appliance Research Institute (CHEARI).
Report scope note The report notes that commissioned testing is responsible only for the received sample, and that sample information was provided by the client. Results should therefore be understood within the test conditions and report scope.
Water Quality Data

Selected water quality results

The JIA HE TESTING report includes water quality test tables for normal-temperature outlet samples. Selected examples from the available report are summarised below.

Test area Selected report result Judgment shown
0 m³ normal-temperature outlet: colour Before: <5. Sample 1: <5. Sample 2: <5. Qualified
0 m³ normal-temperature outlet: turbidity Before: 0.2 NTU. Sample 1: <0.1 NTU. Sample 2: <0.1 NTU. Qualified
0 m³ normal-temperature outlet: odour and taste Before: None. Sample 1: None. Sample 2: None. Qualified
0 m³ normal-temperature outlet: pH Before: 7.29. Sample 1: 6.54. Sample 2: 6.57. Qualified
0 m³ normal-temperature outlet: total hardness as CaCO3 Before: 52.8 mg/L. Sample 1: 2.8 mg/L. Sample 2: 3.2 mg/L. Qualified
0 m³ normal-temperature outlet: TDS Before: 96 mg/L. Sample 1: 9 mg/L. Sample 2: 12 mg/L. Qualified
0 m³ normal-temperature outlet: fluoride Before: 0.27 mg/L. Sample 1: <0.04 mg/L. Sample 2: <0.04 mg/L. Qualified
0 m³ normal-temperature outlet: nitrate as N Before: 2.30 mg/L. Sample 1: 0.31 mg/L. Sample 2: 0.33 mg/L. Qualified
0 m³ normal-temperature outlet: lead Before and samples shown as <0.0005 mg/L. Qualified
0 m³ normal-temperature outlet: chloroform Before: 12.3 μg/L. Sample 1: <0.5 μg/L. Sample 2: <0.5 μg/L. Qualified
0 m³ normal-temperature outlet: total bacterial count Not detected in before sample, Sample 1, and Sample 2. Qualified
0 m³ normal-temperature outlet: total coliforms / E. coli Not detected in before sample, Sample 1, and Sample 2. Qualified
4 m³ normal-temperature outlet: TDS Before: 98 mg/L. Sample 1: 12 mg/L. Sample 2: 14 mg/L. Qualified
Contaminant Reduction

Spiked water test results

The water quality report includes spiked water testing across multiple stages. The report tables show feed values, sample values, removal values, required values, and judgments for selected substances.

Test item Removal range shown in report tables Requirement shown Judgment
Arsenic 99.9% >=83% Qualified
Selenium 99.8–99.9% >=83% Qualified
Chromium VI 98.6–98.7% >67% Qualified
Fluoride 99.8% >75% Qualified
Lead 99.8% >90% Qualified
Nitrate as N 96.3–99.7% >67% Qualified
Chloroform 99.9% >95% Qualified
Carbon tetrachloride 99.8–99.9% >98% Qualified
Important note These values are presented as report-table results for tested samples and test conditions. They should not be read as a universal guarantee for every water source or every usage condition.
Hygiene Safety

Product water and hygiene safety information

The report includes product water tables for normal-temperature and hot-water conditions, including 1-hour and 8-hour test points. Listed indicators include colour, turbidity, odour and taste, visible matter, iron, manganese, copper, sulfate, permanganate index, phenols, cyanide, arsenic, chromium VI, nitrate as N, and lead.

The hygiene safety summary states that after flushing the test machine with purified water according to the manual, purified water was used for soaking at approximately 25°C for 24 hours.

The report summary states that soaking-water indicators including colour, turbidity, odour and taste, visible matter, permanganate index, lead, selenium, mercury, chromium VI, arsenic, phenols, bacterial count, total coliforms and E. coli complied with the applicable hygiene-safety requirements.

Hygiene safety item Selected result shown Judgment shown
Total bacterial count Control: Not detected. Sample 1: 36 CFU/mL. Sample 2: 30 CFU/mL. Qualified
Total coliforms / E. coli Not detected in control, Sample 1, and Sample 2. Qualified
Lead <0.0005 mg/L in control, Sample 1, and Sample 2. Qualified
Arsenic <0.0005 mg/L in control, Sample 1, and Sample 2. Qualified
Mercury <0.00007 mg/L in control, Sample 1, and Sample 2. Qualified
Chromium VI <0.004 mg/L in control, Sample 1, and Sample 2. Qualified
Desalination Performance

Desalination rate result

The available report includes a desalination rate test summary and result table. The testing basis is shown as QB/T 4144-2019 and GB/T 5750-2023, with evaluation basis QB/T 4144-2019.

96.0%

Test item: Desalination rate

Technical requirement: >=90%

Test result: 96.0%

Testing basis: QB/T 4144-2019 and GB/T 5750-2023

Evaluation basis: QB/T 4144-2019

Judgment: Qualified

Important Limitations

Evidence scope notes

The evidence listed on this page is based on the available reports and product information currently provided for the Nova 100. The test results relate to the samples, report conditions, standards, and testing scope shown in the documents.

  • The TÜV Rheinland EMC report relates to the stated tested sample and listed EMC standards.
  • The TÜV Rheinland EMC report records a Pass result for the tested sample.
  • The TÜV Rheinland EMC report states that it does not entitle use of a test mark.
  • The JIA HE TESTING report is an English Translation Version and states that the original sealed Chinese report prevails.
  • The JIA HE TESTING report states that commissioned testing is responsible only for the received sample.
  • The JIA HE TESTING report states that sample information is provided by the client and the organization does not verify its authenticity.
  • Water quality and removal results can vary depending on water source, usage, filter condition, maintenance, and test conditions.
Explore

Related pages

For product details, usage information, and customer support, please review the related Other Water pages below.